>SYNC
LINE LOCK
V PHASE
>
&
0
519 624
PREVIOUS PAGE .
>AGC
>WHITE BALANCE
<ATW Normal>
<ATW Desat>
WHITE BALANCE LIMITS
LOW LIMIT
>
&
2K
2100 5.5K
HIGH LIMIT
&
5.5K
8800 11K
PREVIOUS PAGE .
<AWB>
34
Synchronize the vertical interval sync pulse of your camera with other
equipment to reduce the effect of picture roll on the monitor. Select
either:
<INTERNAL> (default) for cameras using DC power or when line
lock is not required, or
<LINE LOCK> to open the Line Lock screen where you can adjust
the Vertical Phase (V PHASE) from 0 to 624 (519 is the default).
The AGC (Automatic Gain Control) setting affects the day/night
threshold. A higher AGC value results in the camera switching from
day to night mode at lower levels. While observing a video monitor,
adjust the noise in the image, from 0 dB to 36 dB.
Opens the WHITE BALANCE menu where you set how the camera
tracks to accept different lighting conditions within the color range of
2000K to 11000K.
The ATW Normal (default) and ATW Desat options open the WHITE
BALANCE LIMITS screen where you set the Low and High white
balance limits (2100K to 8800K) while observing the video monitor.
ATW Desat is useful for low light conditions.
Opens the PUSH AWB CONFIRM screen where you save your AWB
settings to have them take effect, or select CANCEL.
Auto white balance ensures that color integrity is maintained.
Selecting Save will overwrite all previous settings.