Auto Recovery
Hunter's Auto Recovery feature meets the ENERGY STAR
allowing the heating or cooling system to recover gradually from an energy-saving setpoint
temperature to a comfort setpoint temperature.
Auto Recovery calculates how early to turn your system back On, so that the room tempera-
ture is already comfortable by the start of the comfort temperature program period. Auto
Recovery works in both Heat and Cool modes.
When the thermostat is in Auto Recovery mode, the dis-
play will alternate "RECO" with time, and the program
indicator will flash.
Auto Recovery can be disabled by sliding the Recovery
switch on the circuit board to disable.
Auto Recovery will not operate if Permanent hold or
Temporary hold is in operation.
Auto Recovery can be canceled manually if
HOLD / RETURN is pressed during the recovery process.
Auto Recovery will be canceled and change to Temporary
Manual Override mode if the setpoint is adjusted during
the recovery process.

Error Mode

If the thermostat is unable to control your system due to
an unexpected battery problem, the thermostat will enter
Error Mode. In this condition, the thermostat flashes "Err"
on the LCD display, and shuts off your system. To correct
this problem, replace the batteries with 2 new AA alkaline
batteries, even if you have recently replaced them. Next,
use a paper clip to press the RESET button next to the
keypad. You will need to reprogram your thermostat and
confirm normal operation.
If Error Mode returns, please call Hunter Technical support at 1-866-268-1936 for further
information.
Auto Cut Off
Your thermostat will automatically cut-off in Heat mode if the room temperature rises above
35˚C (95 F). It will cut-off in Cool mode if the room temperature drops below 4˚C (40 F).
Note that if your system has malfunctioned and no longer responds to thermostat controls,
the Auto Cut-Off will have no effect.
®
guidelines for energy efficiency by
2
HEAT TEMP

TROUBLESHOOTING

Problem
No Display
Entire Display Dims
Program Does Not Change
at your Desired Setting
Auto Fan Does Not Turn
On Properly
Heating or Cooling Does
Not Go On or Off
Erratic Display
If unit continues to operate
in the Off position
Thermostat permanently
reads "HI", "LO", or "ERR"
If you experience any other problems, call 1-866-268-1936 from 8 AM to 5 PM Central Time for
technical assistance.
© 2003 Hunter Fan Company
41657-01 06/30/03
Solution
1. Check battery connections and batteries.
2. Press RESET button with a small pin and hold in
for two seconds.
1. Replace Batteries
1. Check that the time is set properly to "AM"
or "PM".
2. Check that the thermostat is not in Permanent
HOLD mode.
3. Check for the correct day setting.
1. Move HG/HE selector to correct position.
1. Check that the function switch is in the correct
position ("HEAT" or "COOL").
2. There may be as much as 4-minute delay before the
system turns On - wait and check. (Compressor
protection delay.)
3. Check your circuit breakers and switches to ensure
there is power to the system.
4. Replace batteries.
5. Make sure your furnace blower door
is closed properly.
6. If your system only uses 4-wires, be sure the jumper
wire is installed between the RC and RH terminals.
1. Press the reset button once with a small pin and
hold for two seconds. Then reprogram.
1. Replace unit.
1. Replace unit.