FS-6020
(3) Detaching and refitting the MP tray feed roller
Perform the following procedure when the MP tray feed roller is to be checked or replaced.
Procedure
1. Remove the process unit.
2. Remove one stop ring.
3. Remove the MP tray feed roller from the
shaft.
4. Replace or Check the MP tray feed roller.
5. Refit all the removed parts.
1-6-10
Stop ring
MP tray feed roller
Figure 1-6-10