Electric And Gas Dryers; Blower Motor Runs But Drum Does Not Turn; Electric And Gas Dryers; Longer Than Normal Drying Times - GE DSXH47EG Technical Service Manual

Hide thumbs Also See for DSXH47EG:
Table of Contents

Advertisement

Electric and Gas dryers; blower motor runs but drum does not turn.

Note: Always check wiring to the components.
Electric and Gas dryers; longer than normal drying times. (Possible E 4A)
Note: Always check wiring to the components.
Yes.
Check washer
spin cycle.
Yes.
Clear vent.
No.
Replace motor.
No.
Level dryer.
Yes.
Review proper
programming of
the control with
the customer.
Drive motor runs but
drum does not turn.
Belt broken or
off pulley.
Longer than normal
drying times.
Are the clothes wetter than normal
when removed from the washer?
No.
Is the vent restricted?
No.
Is the blower motor running
at full speed?
Yes.
Is the dryer level so the clothes
touch the sensor bars?
Yes.
Is the dryer heating properly?
25
No.
Refer to dryer not
heating properly
flow chart.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsxh47gg