Troubleshooting Flow Charts; Electric Dryer Completely Inoperative - GE DSXH47EG Technical Service Manual

Hide thumbs Also See for DSXH47EG:
Table of Contents

Advertisement

Electric dryer completely inoperative.

Note: Always check wiring to the components.
Note: If a fault code is displayed, the dryer will not operate.
Measure the voltage drop
between the red wire on the
thermal limiter and neutral.
0.
Defective household
power supply or
broken wire between
dryer terminal block
and thermal limiter.
Defective thermal

TROUBLESHOOTING FLOW CHARTS

Dryer completely
inoperative.
Does the control beep or
the LED flash when the
start button is pushed?
No.
120VAC.
Measure the voltage drop
between the orange wire
on the thermal limiter and
0.
neutral.
limiter.
120VAC.
Measure the voltage drop
between pins 1 & 2 of the
eight pin plug of the wire
harness to the control
board.
120VAC.
0.
Broken wire between
thermal limiter and the
control board.
Measure the voltage drop
between pins 1 & 2 of J-4.
120VAC.
Defective control
board.
Defective control
board.
23
Yes.
Is an error
code displayed.
Yes.
Refer to error
code chart.
No.
0.
Defective door
switch.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsxh47gg

Table of Contents