Analog Output Operation

In inverter applications it is useful to monitor the
inverter operation from a remote location or from the
front panel of an inverter enclosure. In some cases,
this requires only a panel-mounted volt meter. In other
cases, a controller such as a PLC may provide the
inverter's frequency command, and require inverter
feedback data (such as output frequency or output
current) to confirm actual operation. The analog output
terminal [AM] serves these purposes.
The inverter provides an analog voltage output on terminal [AM] with terminal [L] as analog
GND reference. The [AM] can output inverter frequency or current output value. Note that
the voltage range is 0 to +10V (positive-going only), regardless of forward or reverse motor
C028
rotation. Use
Func.
Code
00
01
02
03
04
05
C028
06
07
08
10
12
15
16
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
to configure terminal [AM] as indicated below.
Description
Inverter output frequency
Inverter output current
Inverter output torque
Digital output freqnency
Inverter output goltage
Inverter input power
Electronic Thermal Load
LAD frequency
Digital current monitor
Cooling fin temperature
General purpose
Pulse train
Option
44
AM H
O OI L
Analog
+
Voltage
A GND
Output
10VDC
full scale,
1mA max
See I/O specs on page 4-6
-