LIK 8TE Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Luft/Wasser- Air-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for air-eau pour Innenaufstellung Indoor Installation installation intérieure Bestell-Nr. / Order no. / N de commande : 452160.66.01...
The heat pump is equipped with an overflow mechanism to pre- vent very low flow rates in the heat pump. The installed buffer tank increases the amount of water in the heating circuit and guarantees reliable defrosting. www.dimplex.de...
Purpose of the Heat Scope of Delivery Pump 3.1 Basic Device 2.1 Application The compact heat pump is supplied complete with all of the im- portant components of the heating circulation system: The air-to-water heat pump is designed for use in existing or Expansion vessel newly built heating systems.
This is done by loosening each of the two screws at the base and then withdrawing the panels by unhooking them from above. Rehang the panels by gently pushing them in an upwards direction. Opening the cover Closing the cover www.dimplex.de...
Set-UP Installation 5.1 General Information 6.1 General Information The heat pump is designed for installation in a corner. Other in- The following connections need to be established on the heat stallation locations are also possible in combination with an air pump: duct (available as an accessory) on the air outlet side.
The control voltage must be protected by a 10 A fuse. For de- the heating system must be flushed to remove any impurities, tailed information, see Circuit Diagrams in the Appendix. residue from sealants, etc. Any accumulation of deposits in the liquifier could cause the heat pump to completely break down. www.dimplex.de...
Start-UP Heat source Max. temperature spread temperature between heating flow and return 7.1 General Information flow From -20 °C -15 °C To ensure that start-up is performed correctly, it should only be -14 °C -10 °C carried out by an after-sales service technician authorised by the -9 °C -5 °C manufacturer.
If in doubt, contact the manufacturer of the chemicals! The buffer tank is drained using the filling and drain cocks on the lower left of the device. Also open the ball valve on the pressure expansion vessel to vent the buffer tank. www.dimplex.de...
11 Device Information Type and order code LIK 8TE Design Model Compact Degree of protection according to EN 60 529 for compact devices IP 20 and heating components Installation location Indoors Performance data Operating temperature limits: Heating water flow/return flow °C / °C...
3.4 Legende / Legend / Légende Drahtbrücke einlegen wenn kein EVU-Sperr- Wire jumper must be inserted if no utility blocking Cavalier à fil à monter en absence de contacteur schütz benötigt wird (Eingang offen = EVU-Sperre contactor is required (contact open = utility block = de coupure du fournisseur d'énergie (pont ouvert = = Wärmepumpe „aus“) heat pump "off").
5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité www.dimplex.de A-XI...