Detergent Dispenser Does Not Open
Possible component failure:
1. Control board
2. Dispenser
120 VAC
Defective
dispenser.
Detergent Dispenser Does
Not Open
Remove the door panel. Run the
diagnostic test for dispenser.
Measure the voltage drop across the
terminals of the dispenser actuator.
Page 42
P3-2
0 VAC
Defective control
board or broken
wire.