Initial Configuration Via Serial Console - P-Link Computer KVM-MU108AP User Manual

8-port/16-port ps/2 kvm over ip switch
Table of Contents

Advertisement

Authentication
To adjust the authentication settings, enter your login as a super user, and change your
password.
Super user login
Enter the login name of the super user. The initial value is "super". All characters are in
lower case.
Super user password
Enter the current password for the super user. This initial value is "pass". All characters
are in lower case.
New super user password
Enter the new password for the super user.
New password (confirm)
Re-type the new password for the super user for confirmation.
To close the window and accept the changes, press the "OK" button; otherwise press the
"Cancel" button.

4.1.1 Initial configuration via serial console

For using serial terminal, the IP-KVM switch has a serial line interface (host side). This
connector is compliant with the RS-232 serial line standard. The serial line has to be
configured with the parameters given in Table 4-2.
When configuring with a serial terminal, e.g., Hyper Terminal, reset the IP-KVM switch and
immediately press the "ESC" key. You will see some device information, and a "=>" prompt.
Enter "config", press "Enter" key and wait for a few seconds for the configuration questions
to appear.
As you proceed, the following questions will appear on the screen. To accept the default
values shown in square brackets below, press "Enter" key.
IP auto configuration (none/dhcp/bootp):
IP [192.168.1.22]:
Net mask [255.255.255.0]:
Gateway (0.0.0.0 for none) [0.0.0.0]:
IP auto-configuration
Parameter
Bits/second
Data bits
Parity
Stop bits
Flow Control
Table 4-2. Serial line parameters
23 / 92
8/16-Port KVM over IP Switch
Value
115200
8
No
1
None