Desa CSG3924NRA Owner's Operation And Installation Manual page 15

Mixing amplifiers unvented (vent-free) gas log heater
Table of Contents

Advertisement

Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the optional CSA design-certified equipment
shutoff valve from your dealer. See Acces-
sories, page 33.
For propane/LP gas, the installer must supply
an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11"
and 14" of water. If you do not reduce incom-
ing gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
13. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Propane/LP
Supply Tank
Figure 13 - External Regulator With Vent
Pointing Down
123639-01D
INSTALLATION
Continued
Installation must include a equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from heater (see
Figure 14.
IMPORTANT: Install equipment shutoff valve
in an accessible location. The main gas valve
is for turning on or shutting off the gas to the
appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged heater valves.
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install sediment trap
in supply line as shown in Figure 14. Locate
sediment trap where it is within reach for
cleaning. Install in piping system between
fuel supply and heater. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
PROPANE/LP
External Regulator
(11" W.C.* to
14" W.C. Pressure)
NATURAL
Meter (5" W.C.**
to 10.5" W.C.
Pressure)
External
Regulator
with Vent
Pointing
Tee
Down
Joint Nipple
Sediment Trap
* Minimum inlet pressure for purpose of input
adjustment.
www.desatech.com
WARNING: Use pipe joint
From
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap
From Gas
3" Minimum
Pipe Cap
Figure 14 - Gas Connection
Approved
Flexible Gas
Hose (if allowed
by local codes)
Gas Control Valve
15