Step 19: Connect Power Supply - GE Built-In Dishwasher Installation Instructions Manual

Built-in dishwasher
Hide thumbs Also See for Built-In Dishwasher:
Table of Contents

Advertisement

Available languages

Available languages

Dishwasher Installation
STEP 18: CONNECT DRAIN LINE (Cont.)
• Connect drain line to air gap, waste tee or disposer
using the previously determined method. Secure hose
with a screw-type clamp.
Method 1 – Air gap with waste tee or disposer
Waste Tee Installation
Figure AB
Method 2 – "High drain loop" with waste tee or disposer
With this method you will need the drain hose hanger set aside
in Step 1.
Fasten drain hose to underside of countertop with the provided
hanger.
Drain Hose Hanger
32"
Min.
18"
Min.
Waste Tee Installation
Figure AC
IMPORTANT –
disposer, check to be sure that drain plug has been removed.
DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE.
Tip: Avoid unnecessary service call charges for a no drain
complaint.
Make sure excess drain hose has been pulled through
the cabinet opening. This will prevent excess hose in the
dishwasher cavity from becoming kinked or crushed by the
dishwasher.
Disposer Installation
32"
Min.
18"
Min.
Disposer Installation
When connecting drain line to
Remove
Drain
Plug

STEP 19: CONNECT POWER SUPPLY

If a power cord with plug is already installed proceed to
Step 20.
WARNING:
If house wiring is not 2-wire with ground, a ground must be
provided by the installer. When house wiring is aluminum, be sure
to use UL-Listed anti-oxidant compound and aluminum-to-copper
connectors.
In this step you will need the junction box cover and the
#10 Hex head screw from the screws set aside in Step 1.
• Secure house wiring to the back of the junction box with a
strain relief.
• Locate the 3 dishwasher wires, (white, black and green) with
the stripped ends coming out of the AC jumper. Use UL listed
wire nuts of appropriate size to connect incoming ground to
green, white to white and black to black.
• Install the junction box cover using #10 hex head screw.
Check to be sure that wires are not pinched under the cover.
• Make sure that the junction box cover is resting on the
mounting bracket.
• If using a Power Cord Kit, please refer to the included
instructions.
NOTE: Do not remove the
Junction Box Bracket.
Ground
White
(Green)
Black
Figure AD
AC
Jumper
Junction Box
Bracket
Ground Screws
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents