OpTIONAL FBB5 SINGLE SpEED BLOwER INSTALLATION INSTRUcTIONS

Attention: It is recommended to install the blower assembly be-
fore connecting gas inlet supply line.
wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. This appliance is equipped with
a three-prong [grounding] plug for your protection against
shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. For an ungrounded receptacle,
an adapter, which has two prongs and a wire for grounding, can be
purchased, plugged into the ungrounded receptacle and its wire
connected to the receptacle mounting screw. With this wire com-
pleting the ground, the appliance cord plug can be plugged into the
adapter and be electrically grounded.
caution: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
Note: Junction box on right side of fireplace must be pre-wired at
time of fireplace installation for use with blower assembly.
A standard wall ON/OFF wall switch or optional SCV1 Vari-
able Speed Control Kit should be installed to activate pow-
er to the fireplace, and control the operation of the FBB5
Blower assembly. It is recommended that installation of the
wiring be performed by a qualified electrician. See Figure
20.
1. If installed, turn OFF gas supply to firebox/gas log.
2. If applicable, turn OFF electric supply to firebox.
cAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-
FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE
MAKING THE ELECTRICAL CONNECTION, MAKE SURE
THAT MAIN POWER SUPPLY IS DISCONNECTED. THE
APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICAL-
LY GROUNDED IN ACCORDANCE WITH LOCAL CODES,
WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70
(LATEST EDITION).
33743-2-0315
Figure 20
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction box
and attached to the receptacle that is provided. From right
side of the fireplace, remove the screw securing the junction
box assembly. Leave approximately 6" of wire in the junction
box for connection.
Attach black wire to one side of the receptacle and white wire
to opposite side of receptacle. The ground wire should be at-
tached to the green (ground) screw.
Attention: If installed, do not damage gas inlet supply line
when blower assembly is inserted into firebox. In some cases,
removal the gas inlet supply line may be necessary.
For Vent Free Fireboxes
1. Determine which type of firebox you have prior to installation.
See Figures 21 through 23.
Deluxe Louvered Models
Figure 21 (Deluxe Louvered shown)
Deluxe Flush Face and premium Models
Figure 22 (Deluxe Flush shown)
Select Firebox Models
Figure 23