Basic Device

The basic device consists of a ready-to-use heat pump for indoor
installation, complete with sheet metal casing, control panel and
integrated control system. The refrigerating cycle contains the re-
frigerant R407C. R407C refrigerant is CFC-free, non-ozone de-
pleting and non-combustible.
All components required for the operation of the heat pump are
located on the control panel. The power feed for the load current
and the control current must be installed by the customer.
The collector including the brine manifold must be provided by
the customer.
1)
Liquifier
2)
Control panel
3)
Compressor
4)
Heating pump
5)
Evaporator
6)
Primary pump
www.dimplex.de
4

Accessories

4.1 Brine circuit manifold

The brine circuit manifold merges the individual collector loops of
the heat source system into a single main pipe which is con-
nected to the heat pump. Integrated ball valves allow the individ-
ual brine circuits to be shut off for de-aeration purposes.
5

Transport

A lift truck is suited for transporting the unit on a level surface.
Carrying straps may be used if the heat pump needs to be trans-
ported on an uneven surface or carried up or down stairs. These
straps can be passed directly underneath the wooden pallet.
ATTENTION!
The heat pump is not secured to the wooden pallet.
ATTENTION!
The heat pump must not be tilted more than 45° (in any direction).
Use the holes provided in the sides of the frame to lift the unit
without the pallet. The side panel assemblies must be removed
for this purpose. Any commercially available length of pipe can
be used as a carrying aid.
ATTENTION!
Do not use the holes in the panel assemblies for lifting the device!