VENTING
This is a Direct Vent Gas Water Heater where all air for combustion is
obtained from the outside atmosphere and all flue gases are discharged to
the outside atmosphere.
The vent-air intake system must be properly installed. Failure to
properly install the vent-air intake system properly could result in
property damage, personal injury or death.
DO NOT install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.
Direct Vent Terminal Clearances
A=
Clearance above grade, veranda,
porch, deck or balcony
B=
Clearance to widow or door that may
be opened
C=
Clearance to permanently closed
widow
D=
Vertical clearance to ventilated soffit
located above the terminal within a
horizontal distance of 2 feet (61 cm)
from the center line of the terminal
E=
Clearance to unventilated soffit
F=
Clearance to outside corner
G=
Clearance to inside corner
H=
Clearance to each side of center line
extended above meter/regulator
assembly
WARNING
Figure 4
2
Canadian
US Installations
1
Installations
12 inches (30
12 inches
cm)
(30 cm)
12 inches (30
9 inches (23 cm)
cm)
*b
*b
12 inches (30
12 inches (30
cm) *a
cm) *a
12 inches (30
12 inches (30
cm) *a
cm) *a
*b
*b
*b
*b
3 feet (91 cm)
*b
within a height
15 feet (4.6 m)
above the
meter/regulator
assembly
11