American Water Heater DIRECT VENT GAS WATER HEATER Installation And Operating Instruction Manual page 22

American water heater co direct vent gas water heater installation and operating instruction manual
Table of Contents

Advertisement

Installation (Vent-Air Intake System Installation) continued-
11. From inside the building, slide the backing plate over the five (5) inch
(12.7 cm) diameter telescopic tube until it is flush with the wall. Adjust
the length of the five (5) inch (12.7 cm) diameter telescopic tube and
insert the end into the flared end of the five (5) inch (12.7 cm) diameter
elbow one (1) inch (2.5 cm) (or until seated). Drill three (3) 1/8 inch
o
diameter holes, 120
apart, through the five (5) inch (12.7 cm) diameter
elbow into the five (5) inch (12.7 cm) diameter telescopic tube and
through the tubes where the small and large sections overlap. Fasten
with three (3) #8 sheet metal screws (supplied). Using the supplied
special RTV silicone sealant, apply a sufficient amount to seal all joints
(See Figure 14).
Figure 14
Figure 13
22

Advertisement

Table of Contents
loading

Table of Contents