Table 2-10
I/O Expansion Cabinet Power Requirements (Without Support
Management Station)
Requirement
Nominal input voltage
Input voltage range (minimum to maximum)
Frequency range (minimum to maximum)
Number of phases
Marked electrical input current
Maximum inrush current
Power factor correction
Table 2-11
I/O Expansion Cabinet Component Power Requirements
Component
Fully configured cabinet
I/O card cage
ICE

I/O Expansion Cabinet Power Cords

Table 2-12 lists the power cords for the I/O expansion cabinet.
Table 2-12
I/O Expansion Cabinet ac Power Cords
Part Number
A5499AZ
-001
-002
Chapter 2
Where Used
North America
International
Value
200/208/220/230/240 V ac rms
170-264 V ac rms
50/60 Hz
1
16 A
60 A (Peak)
0.95 minimum
Component Power Required
50 Hz to 60 Hz
3200 VA
500 VA
600 VA
Connector Type
L6-20
IEC 309
System Specifications
Electrical Specifications