    AIR CONDITIONER OPERATING MANUAL Ceiling Suspension Type Keep this manual for future reference FUJITSU GENERAL LIMITED PART NO. 9374379590-02...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS .........2 SWING OPERATION ..........12 FEATURES AND FUNCTIONS ........3 ECONOMY OPERATION ........12 NAME OF PARTS ............4 10 °C HEAT OPERATION ........13 PREPARATION ............6 SELECTING THE REMOTE OPERATION .............7 CONTROLLER SIGNAL CODE ......13 TIMER OPERATION ..........9 CLEANING AND CARE ..........14 SLEEP TIMER OPERATION ........10 TROUBLESHOOTING ...........15 MANUAL AUTO OPERATION ........10...
  • Page 3: Features And Functions

    SAFETY PRECAUTIONS This appliance is not intended for use by persons (including children) with ● CAUTION reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Page 4: Wireless Remote Controller

    FEATURES AND FUNCTIONS [The additional functions for wired ones] n Remote controller • Weekly timer • Temperature set back timer WIRELESS REMOTE CONTROLLER And you can use both wired and wireless remote controller simultaneously. The wireless remote controller allows convenient control of (But function is limited) air conditioner operation.
  • Page 5: Remote Controller

    NAME OF PARTS Remote controller Display panel Display To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual operation, however, the display will only show those indi- cators appropriate to the current operation. 1 MODE button F Signal transmitter 2 10 °C HEAT button G Temperature SET indicator...
  • Page 6: Preparation

    PREPARATION CAUTION Turn on the Power Take care to prevent infants from acci- ● dentally swallowing batteries. Turn on the circuit breaker. When not using the remote controller for ● an extended period, remove the batteries to avoid possible leakage and damage to Load Batteries (Size AAA R03/LR03 ×...
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION indicator lamp (green) will light. The air conditioner will start operating. Press the MODE button to select the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL HEAT...
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Stop Operation Press the START/STOP button. The OPERATION indicator lamp (green) will go out. Mode operation AUTO (in COOLING model): ● When AUTO (automatic changeover) operation first selected, the fan will oper- Cooling mode ate at very low speed for about a few minutes, during which time the indoor or Dry mode...
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the remote controller is set to the correct current time (☞ Page 6). If the indoor unit is connected to a wired remote controller, the wireiess remote controller cannot be used to set the timer. To Use the ON Timer or OFF Timer Press the START/STOP button To Cancel the Timer...
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the sleep timer.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). ● Adjust the up, down, left and right air directions with the SET buttons on the remote controller. ● Use the SET buttons after the indoor unit has started operating and the airflow-direction louvers have stopped moving. Vertical Air Direction Adjustment DANGER Press the SET button (Vertical).
  • Page 12: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button. Each time the SWING button is pressed, the swing operation will change in the following order. Left/right swing operation Up/down swing operation Swing operation stops Up/down/left/right swing operation To stop SWING Operation...
  • Page 13: 10 °C Heat Operation

    10 °C HEAT OPERATION To use 10 °C HEAT Operation While 10 °C HEAT operation is in progress, only the following operation can be used. Press the 10 °C HEAT button. • SWING The OPERATION indicator lamp (green) will go out, and the ECONOMY indicator lamp (green) will light.
  • Page 14: Cleaning And Care

    CLEANING AND CARE CAUTION ● Before cleaning the air conditioner, be sure to turn it off and turn off the electrical breaker. ● To avoid excessive wear of the part and components or malfunctioning of the air conditioning, the user/consumer shall perform preventive maintenance through an accredited technical assistance, periodically.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING power supply plug or turn off the circuit breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 16 TROUBLESHOOTING Symptom Problem See page CHECK ONCE Does not operate at all: ● Has the circuit breaker been turned off? MORE ● Has there been a power failure? — ● Has a fuse blown out, or a circuit breaker been tripped? ●...
  • Page 17: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Microcomputer-controlled Automatic Defrosting* ● This air conditioner operates on the heat-pump principle, ● When using the heating mode under conditions of low out- absorbing heat from outdoor air and transferring that heat door temperature and high humidity, frost may form on the indoors.