Safety Tips For Installation - Toyostove Laser 73 Installation And Operation Instructions Manual

Laser clean heating system/vented heater
Hide thumbs Also See for Laser 73:
Table of Contents

Advertisement

Follow the safety tips below when planning the installation of your Laser 73. 
1.
Intake and exhaust flue pipe openings must be fully exposed to outside air. 
Do not vent into chimney, garage, basement under the floor, or into any
enclosed area.
2.
Do not install flue pipe in close proximity to other objects or materials (See
page 23).
3.
Before making a hole in your wall for the flue pipe, make sure the area is free
of electrical wires, gas pipes and other obstacles.
4.
Do not install flue pipe where it will be exposed to heavy snow collected leaves
or strong drafts.
Important:
In areas of hea-
vy snow falls,
ground surface
clearance must
be increased
according to
average snow
falls.
5.
Do not install the flue pipe down from the heater.
6.
Total length of extension pipe between heater and flue pipe must be no
greater than 10 ft. and 3 bends may be used.
NOTE: When using extension pipes always cover the exhaust pipe with the
insulating cloth cover.
7.
A B-Vent shall not be used in the vent system.
For all prescribed heater installations, the flue pipe must always be installed
in a horizontal position.
22

SAFETY TIPS FOR INSTALLATION

SAFETY TIPS FOR INSTALLATION
Important:
In open area
Long
with strong
extension
kit
Must be
wind, a wind
higher
break may be
necessary.
Snow
Snow
Strong
wind
24"(Min.)
Wind
break
Gas pipe

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Laser 73at type mLaser 73 type mLaser 56

Table of Contents