Safety Features - Toyostove Laser 73 Installation And Operation Instructions Manual

Laser clean heating system/vented heater
Hide thumbs Also See for Laser 73:
Table of Contents

Advertisement

Your Laser 73 is equipped with the following safety features. Please familiarize yourself with these features.
When your heater is extinguished due to a safety mechanism, be sure to identify and correct the problem.
1.
Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order
to prevent fuel overflow. Error code will be displayed on the digital indicator.
Fuel Strainer
2.
Special strainer catches any dirt or impurities present in the fuel before it is sent to the burner.
3.
Overheat Protector
Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor
malfunction or abnormal combustion, in order to prevent fire.
4.
Power Failure Recovery System
If power fails during heater operation, heater will turn off. When power resumes, heater will
automatically reignite to maintain the selected room temperature.
5.
Fully Vented System
Flue pipe system provides outside air for combustion and vents all combustion products to the
outdoors.
6.
Fusible Link Valve
If a household fire should occur, bringing the fuel line or heater to extremely high temperatures, the
fusible link valve will stop the fuel supply to the burner. This will prevent the fuel supply from the
external tank continuing to flow into the house.

SAFETY FEATURES

3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Laser 73at type mLaser 73 type mLaser 56

Table of Contents