Step 4: Insert the conduit from the Power Vent module into the rough-in frame
through the two top right entry holes. Remove the nut from the supplied strain
relief and place as show in Figure 13c.
Figure 13c. Installing Power Vent Conduit.
Step 5: Securely fasten bottom collar pan into rough-in frame using the
existing hardware, 4-pieces. Tighten strain relief nut onto strain relief.
Step 6: Pull Power Vent connector from behind half way through supplied
hole in conduit mounting frame. Snap into place, notches in two plastic
wing clip. See Figure 13d.
Strain Relief & tightened nut
Tightened hardware, 4-pcs.
Figure 13d. Installing conduit connector and conduit mounting frame.
Page 22
Installation
Strain Relief
Power Vent Harness
Strain Relief
Nut
Power Vent Harness
Conduit
mounting
frame
Power Vent
Connector
Step 7: Fasten conduit mounting frame into place using existing
hardware, six pieces. Coil conduit behind cover. See Figure 13e.
Figure 11e. Assembled Rough-in Kit.
Step 8: Install the Power Vent power harness. Hold the Power Vent in
close proximity to the assembled Rough-in Kit. Plug in the Power Vent
harness. See Figure 13f.
Figure 13f. Installation of Power vent harness.
Step 9: Install the Power Vent. Place the Power Vent into the rough-in
frame, aligning the Power Vent into final position. Ensure the power
harness is placed down in the rough-in frame when placing the Power
Vent. Secure the Power Vent in place with the supplied hardware, 4
pieces. See Figure 13f.
Tightened hardware,
4-pcs.
Figure 13g. Completed Power Vent installation.
Installed Power Vent
Connector
Tightened hardware, 6-pcs.
Power Vent
Harness.
TOP of Power Vent
Note louver
direction