Lenovo ThinkCentre 6416 Maintenance Manual page 69

Thinkcentre lenovo
Table of Contents

Advertisement

Diagnostic Error Code
018-250-XXX
PCI Card Services error
020-000-XXX
PCI Interface Test Passed
020-0XX-XXX
PCI Interface error
020-195-XXX
PCI Test aborted by user
020-196-XXX
PCI test halt, error threshold exceeded
020-197-XXX
PCI test warning
020-198-XXX
PCI test aborted
020-199-XXX
PCI test failed, cause unknown
020-262-XXX
PCI system error
025-000-XXX
IDE interface Test Passed
025-00X-XXX
025-01X-XXX
IDE interface failure
FRU/Action
1. PCI card
2. Riser card, if installed
3. System board
No action
1. PCI card
2. Riser card, if installed
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a
CD-ROM or diskette" on page 152
3. Go to "Undetermined problems" on page
78
1. Go to "Undetermined problems" on page
78
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a
CD-ROM or diskette" on page 152
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 7. Symptom-to-FRU Index
63

Advertisement

Table of Contents
loading

Table of Contents