Maintenance and Modifications, cont'd
2.
(HSA 222 models only) Remove the four Phillips head
screws from the front access panel (figure 3-1). Retain the
screws. Lift the panel away from the enclosure.
Remove
front access
panel.
Figure 3-1 — Removing the front access panel
(HSA 222 models)
HSA 200/222 Series • Maintenance and Modifications
3-4
3.
(HSA 222 models only) Disconnect both RJ-45 connectors
from the underside of the enclosure by simultaneously
performing steps 3a and 3b:
a.
With a Tweeker in one hand, reach through the small
access hole in the front of the enclosure (figure 3-2)
and gently pry outward on the front of the RJ-45
connector detent on the bezel plug-in,
— while you —
b.
Reach your other hand through the front panel access
hole and tilt the connector back.
This disconnects the connector from the interior of the
lower enclosure without damaging the bezel plug-in.
Figure 3-2 — Releasing the bezel plug-in detent
(HSA 222 models)