Ariens Sierra 936014-026 Service Manual page 49

Ariens sierra lawn mower service manual
Table of Contents

Advertisement

Key Switch
B
A
S-1
S-2
Contact Resistance Is 0.1-0.3 Ohms When Correct.
Seat Switch
Pink
Black
Normally Open Contacts Manually Activated. Contact Resistance Is 0.1-0.3 Ohms When Correct.
PTO Switch
Yellow/red (2)
Purple/white (2)
Purple
Brown/yellow
2 Sets Of Contacts, One Normally Open, One Normally Closed. Contact Resistance Is 0.1-0.3 Ohms When
Correct
Brake Switch
Brown/yellow
Red/violet (3)
Normally Open Contacts Manually Activated. Contact Resistance Is 0.1-0.3 Ohms When Correct.
Relay #1
Pink
85
Purple
Yellow/red
87a
Purple (3)
Pins 85-86 Coil Resistance 87-100 Ohms. Pins 30-87 Normally Open. Pins 30-87a Normally Closed. Contact
Resistance Is 0.1-0.3 When Correct.
Off
11:50-13:00
Off
Off
Off
Off
86
87
30
Run
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
Run
11.50-13.00 Vdc
Connected To Ground
Run
11.50-13.00 Vdc
Connected To PTO Clutch And Light
11.50-13.00 Vdc
11.50-13.00 Vdc
Run
11.50-13.00 Vdc
11.50-13.00 Vdc
Run
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
Not Used
11.50-13.00 Vdc
11 - 49
Start
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
Start
11.50-13.00 Vdc
Start
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
Start
11.50-13.00 Vdc
11.50-13.00 Vdc
Start
11.50-13.00 Vdc
11.50-13.00 Vdc
11.50-13.00 Vdc
Not Used
11.50-13.00 Vdc

Hide quick links: