The "M" tells the 232SS2 it is the set timer mode command and the
"1" indicates to set up the timer to ignore switching commands.
When the timer is configured in this mode, the 232SS2 will not
accept any switching commands ("A", "B", "C", "D", or "EOT") for the
specified timer value. After the timer has expired, the slave port that
is connected to the master port will be disconnected. This feature is
useful to prevent inadvertent switching during binary/graphic type file
transfers. For example (smart switch mode): The timer is
configured to ignore switching commands for 5 seconds. The select
Port D command is sent to the 232SS2. Once Port D is connected a
file of unknown data type (so file may or may not contain a switching
command sequence) is to be transferred through the 232SS2. For a
period of 5 seconds after Port D is connected, no switching
commands will be accepted. As long as the file transfer takes less
than 5 seconds, there is no chance the 232SS2 will inadvertently
switch ports.
Function
Select Port A
Select Port B
Select Port C
Select Port D
Deselect Port
Set Timer Value
Set Timer Mode
*X represents the programmable character set by dipswitch SW2
**NU = Not Used

Specifications

Model:
232SS2
Size:
6.2 x 8.0 x 2.5hin
Power: 12Vdc to 16Vdc @ 100mA
232SS21600Manual
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
Table 4 - 232SS2 Commands
Command Characters
1st
2nd
ESC
X*
ESC
X*
ESC
X*
ESC
X*
ESC
X*
ESC
X*
ESC
X*
3rd
4th
"A"
NU**
"B"
NU**
"C"
NU**
"D"
NU**
EOT
NU**
"T"
"0"-"9"
"M"
"0","1"
Comments
Switching
Command
Switching
Command
Switching
Command
Switching
Command
Switching
Command
Enhanced
Mode
Enhanced
Mode