Bradford White POWERED DIRECT VENT SERIES GAS-FIRED COMMERCIAL WATER HEATER Installation & Operation Manual page 27

Powered direct vent series gas-fired commercial water heater
Table of Contents

Advertisement

Shown flashing
in display only when
temp is adjusted
Sequence of
operation Indicator
Reads "Idle" or "Heating"
Status Indicator
Read "Operational"
or "Service Needed"
Select button
If the water heater display does not show "Operational" in the "Status" indicator, there may be an operating
malfunction with the water heater. If this is the case, a numeric code will be displayed. Refer to the label next to the
display for the definition of the error code and call your plumbing professional or service agent to service the water
heater. Do not try to reset the water heater without having a qualified service person to diagnose and correct the
problem. If the display is blank or does not show an error code, make sure there is power to the water heater.
Setting the water temperature to the maximum set point can result in scalding hot water delivered to the faucets. It
is highly recommended that the maximum setpoint be adjusted to the lowest temperature possible for the needs of
the installation. See following section to change the maximum setpoint limit (max setpoint). Make sure the water
heater control display is not in a public area that can result in the temperature settings being improperly adjusted.
See previous warning on scalds and an ASSE approved mixing valve.
When the maximum setpoint is reached, the display will show "Max Setpoint" without the setpoint value. The
maximum setting is equal to approximately 180˚F (82˚C).
The default temperature setpoint from the factory is 70˚F (21˚C).
Water Heater Display and Control Buttons
idle
Status
Operational
SELECT
WARNING
NOTICE
setpoint
°F
SET
27
Temperature
Up Button
Temperature Setpoint
in Degrees F or Degrees C
Range 70 - Max °F
Range 21 - Max °C
Temperature
Down Button
Set button