It is acceptable to install a 90 degree elbow on IPEX concentric vent terminations use with this power direct vent water
heater (see Figure 23b). A short length of appropriate diameter vent pipe should be used to transition from the vent
terminal to the 90 degree elbow. Approved venting materials along with primers and cements are listed at the beginning
of this venting section. When the 90 degree elbow is used the equivalent length of the elbow and short length of vent
pipe must be factored into the total vent/air intake pipe determinations (see Tables 3 and 4 for appropriate vent
connector lengths).
(A) VENT DIAMETER

VENT PIPE PREPARATION

DO NOT attempt to start this water heater until vent pipe solvent fumes completely
clear from the room and inside the vent piping.
2" (5.1 CM)
3" (7.6 CM)
Figure 23B
(B) DIMENSION
MIN
12" (30.5 CM)
12" (30.5 CM)
WARNING
35
WARNING! DO NOT
USE 2" VENT WITH
EF100T250/300
MODELS
MAX
40" (101.6 CM)
44" (111.8 CM)