WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT USE OR STORE FLAMMABLE
MATERIALS NEAR THIS APPLIANCE.
• DO NOT SPRAY AEROSOLS IN THE VICIN-
ITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• DO NOT PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
This is a room sealed appliance and no other ventilation is
required than what is provided.
SAI Global
Ref No GSCS20162
AS4553:2008
1

Advertisement

Table of Contents
loading

Summary of Contents for Hearth and Home Technologies 350TRSI-AUF

  • Page 1 • Installation and service must be performed This is a room sealed appliance and no other ventilation is by a qualifi ed installer, service agency, or the required than what is provided. gas supplier. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215 Street West, Lakeville, MN 55044 Copyright 2010 • Printed in U.S.A. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 3: Congratulations

    The model information regarding your specifi c fi replace can be found on the rating plate usually located in the control area of the fi replace. Type of Gas SAI Global Certification Nº: DMS (mm) Model Number Serial Number Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 4: Table Of Contents

    E. Control Module Operation ......54 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 5 E. Contact Information ......79 Î = Contains updated information. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 6: Limited Lifetime Warranty

    B. Limited Lifetime Warranty Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 7 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 8: Listing And Code Approvals

    DMS 55 (1.70 mm) Pilot Injector .0121 0.0181 An in-line regulator MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 9: User Guide

    (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 9.E. MANTEL SECTION 5.D FAN KIT SECTION 2.C. HEARTH CLEAR SPACE SECTION 2.D. GRATE Figure 2.1 General Operating Parts Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 10: Fan Kit

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 12: Control Module Operation

    This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 13: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 14: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 15: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 16: Installer Guide

    HEATER MUST BE INSTALLED AND MANTEL AND FLUE PENETRATION COMPLETE MANTEL LEG PRIOR TO FINISH SHEETING (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 17: Design And Installation Considerations

    Reciprocating saw Manometer Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 18: Framing And Clearances

    76 mm 40-1/4 48-1/2 16-1/2 13-1/2 7-1/2 34-3/4 27-3/4 42-5/8 5-7/8 68-3/4 350TRSI-AUF See Section D. 350TRSILP-AUF Mantel Projections 1023 864 1423 1232 1082 1737 Figure 5.1 Appliance Locations Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 19: Constructing The Appliance Chase

    2 in. X 4 in. (51 x 102 mm) lumber or heavier. The framing headers may rest on the heater standoffs. Refer to Figure 5.1 and Figure 5.3 for heater and framing reference dimensions. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 20 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 in. (305 mm) for rear venting with one 90º elbow. Figure 5.3 Clearances to Combustibles Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 21: Mantel And Wall Projections

    (Acceptable on both sides of opening.) HIGH TEMPERATURE (150 ºC MIN.) TOP AND SIDE SEAL JOINT Note: Zero clearance fi nishing allowed on sides of surround and top of non-combustible board. Figure 5.7 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 22: Termination Locations

    53.1°-56.3° ............2 130 56.3°-59.0° ............2 290 59.0°-60.3° ............2 440 *910 mm minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 23 LP Gas cylinder. A fl ue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 6.3 Minimum Clearances for Termination Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 24: Vent Information And Diagrams

    • When penetrating a combustible ceiling, a ceiling fi restop must be installed. • Horizontal runs of vent do not require vertical rise; Horizontal horizontal runs may be level. Figure 7.1 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 25 SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal Note: A 152 mm section of straight fl ue must be attached to the heater before a 90° elbow. USE SLP SERIES COMPONENTS ONLY Figure 7.4 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 26 10 ft. 3.05 m 30 ft. 9.14 m 10 ft. 3.05 m = 30 ft. (9.14 m) Maximum = 10 ft. (3.05 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 27 3.66 m = 6 ft. (1.83 m) Maximum *H = 12 ft. (3.66 m) Maximum = 32 ft. (9.75 m) Maximum = 36 ft. (10.97 m) Maximum Figure 7.6 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 28 Failure to keep insulation or other material away from vent pipe may cause over heating and fi re. For alternative installations, other than depicted, contact your dealer for further information. Figure 7.7 RESTRICTOR PLATE Figure 7.8 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 29: Flue System Approvals And Installations

    PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP Flue system termination kits DVP-SERIES SLP SERIES DVP-TVHW DVP-TRAP2 DVP-FBHT SLP-TRAP2 SLP-TVHW Figure 7.9 Flue Components and Terminations Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 30 1.52 m 16 ft. 4.88 m = 36 ft. (10.97 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 32 ft. (9.75 m) Figure 7.10 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 31 Note: A 152 mm section of straight fl ue must be attached to the heater before a 90° elbow. USE SLP SERIES COMPONENTS ONLY INSTALLED HORIZONTALLY Figure 7.11 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 32: Rear Vent - Horizontal Termination

    USE DVP SERIES COMPONENTS ONLY Figure 7.12 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. USE DVP SERIES COMPONENTS ONLY Figure 7.13 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 33 1.83 m 10 ft. 3.05 m INSTALLED HORIZONTALLY = 30 ft. (9.14 m) Maximum = 4 ft. (1.22 m) Maximum = 10 ft. (3.05 m) Maximum Figure 7.15 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 34 4 ft. 1.22 m 10 ft. 3.05 m = 32 ft. (9.75 m) Maximum = 9 ft. (2.74 m) Maximum USE DVP SERIES COMPONENTS ONLY INSTALLED HORIZONTALLY Figure 7.17 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 35 *No specifi c restrictions on this value EXCEPT cannot exceed 32 ft. (9.75 m) Maximum = 8 ft. (2.44 m) Maximum USE DVP SERIES COMPONENTS ONLY INSTALLED Figure 7.18 HORIZONTALLY Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 36: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one 25.4 mm above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 37: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 38: Install Attic Insulation Shield

    These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to Figure 8.6 Heat Zone Knockout maintain air space clearance. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 39: Appliance Preparation

    The heat shield must remain in the vertical position. 2 SCREWS Figure 9.3 Replace the two screws as shown. Figure 9.6 Remove the insulation from the outer vent pipe. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 40: Rear Vent

    Use two self- tapping screws to secure gasket to outer wrap. Figure 9.9 Cut the metal retaining band and fold the sides out. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 41: Installing The Non-Combustible Board

    PILOT HOLES • Bend out nailing tabs on each side. • Place the appliance into position. Figure 9.16 Proper Positioning and Securing of an Appliance Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 42: Covers Removal For Servicing

    9.5 mm the top two screws locating the pilot bracket (see Figure 350TRSILP-AUF 11 mm 12.5 mm Î 9.18). Slide the burner away from the burner orifi ce. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 46: Install Support Brackets

    • The pipe opening of the fi restops MUST BE placed towards the bottom of the fi restop. Figure 10.14 Hole and New Framing Members • Continue the fl ue run through the fi restop. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 47: Flue Termination

    • The small leg in the shield rests on top of the fl ue to properly space it from the pipe section (see Figure 10.17). Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 48: Heat Shield Requirements For Horizontal Termination

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.20. CAUTION! Risk of Fire! Follow the requirements of the Australian gas installation code for minimum height re- quirements above the roof. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 49: Assemble And Install Storm Collar

    • Caulk around the top of the storm collar (see Figure 10.23). BRACKETS (1 of 3) STORM COLLAR Figure 10.21 Assembling the Storm Collar SCREWS CAULK Figure 10.23 Figure 10.22 Assembling the Storm Collar Around the Pipe Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 50: Gas Information

    DMS 55 (1.70 mm) Pilot Injector .0121 0.0181 An in-line regulator MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 51 fl ame. Fittings and connections could have loos- ened during shipping and handling. Figure 11.1 WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 52: Electrical Information

    HARNESS TO OPTIONAL COMPONENTS OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) (MAIN) BLACK BATTERY PACK 6V DC (C X 4) BROWN GROUND Figure 12.1 IPI Wiring Diagram /RC300AU Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 53: Blower

    The access hole for con- (NEUTRAL) BLUE BLUE necting the service wires is found on the right exterior side BLUE of the unit. See Figure 12.3 for wire connection detail. Figure 12.3 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 54: Control Module Operation

    This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 55: Installation Precautions

    The RC300AU is approved for interior installation and should not be used in exterior applications. • Keep remote control out of reach of children. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 56 Figure 12.7 Remote in Housing Figure 12.5 Temperature Scale 5. Close the housing door. See Figure 12.8. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 57: Fan Installation

    3 steps, timer based, MED and LOW 7 min. ON, 12 min. OFF FAN CORD LEARN BUTTON Figure 12.11 Programming RC300AU AUX 300 MODULE Figure 12.10 Plug Fan into AUX300CE Module Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 58 Use the SELECT button to select the current Select feature. Use the UP and DOWN arrows to toggle through the menu functions and value selec- tions in the submenus. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 59: Adjusting Flame Height

    fi replace is turned on. and AUX2 settings will be restored to the previous setting. NOTICE: The system will remember the previous FLAME HEIGHT setting and will automatically adjust after 10 seconds. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 60: Power Outage

    NOTICE: No functions will be usable until child lock feature • Locate house circuit breaker for fi replace. is disabled. • Turn off the circuit breaker. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 61 At control module, turn off fi replace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 62: Finishing

    350TRSI-AUF Millimeters 2-7/8 IN. 350TRSILP-AUF MINIMUM 3 FT. MAXIMUM Figure 13.3 Noncombustible Facing Diagram Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 63: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. DO NOT MODIFY THIS APPLIANCE Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 64: Log Placement Instructions

    Locate the bottom groove of log #2 over the left most grate tine and align over Î the burner by placing the log slot over the burner tab as shown. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 65 LOG #5 (SRV438-724): Î Locate the top of log #5 onto log #1 and log #3, and place the bottom on the right side of the fourth grate tine. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 66 Î Place log #6 against the second and third grate tines. If sooting occurs, the logs might need to be repositioned slightly to avoid excessive fl ame impingement. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 67: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 68 B. Shutter Setting Check to assure correct shutter setting for your model and gas type. C. Gas Type Assure correct fuel matches unit gas model and components. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 69: Reference Materials

    Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Ø GAS LINE ACCESS Ø ELECTRICAL ACCESS Location Millimeters Location Millimeters Figure 16.1 Appliance Dimensions Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 70: Maintenance Tasks

    2. Replace batteries in remote transmitters and battery-powered receivers. Carbon Deposition 1. Appliances incorporating a live fuel effect, and designed to operate with luminous fl ames, may exhibit slight Î carbon deposition. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 71: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.3 DVP vent components Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 72 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 16.4 DVP vent components Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 73 13-1/4 in. (367 mm) 14 in. 27-1/2 in. (356 mm) 24-5/8 in. (127 mm) (625 mm) DRC-RADIUS RF6M Cap Shield Roof Flashing Multi-pak Figure 16.5 DVP vent components Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 74 2 - 6 51 - 152 SLP-PIPE Wall Shield Firestop SLP12A 2 - 12 51 - 305 SLP-HVS SLP-FS Horizontal Pipe Ceiling Firestop Support Figure 16.6 SLP Series Vent Components Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 75 Trap2 12 in. 133 mm 235 mm Length (305 mm) SLP-TRAP2 Horizontal Termination Cap SLP-TVHW Vertical Termination Cap DVP-FBHT DVP-FBHT SL-2DVP SLP90 Figure 16.7 SLP Series Vent Components Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 76: Service Parts

    350TRSI-AUF, 350TRSILP-AUF D. Service Parts Beginning Manufacturing Date: July 2010 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 77 N2PB-350I-AUF Propane to Butane P2B-350I-AUF Propane/Butane to Natural PB2N-350I-AUF Pilot Orifi ce N .0181 2098-518 Pilot Orifi ce B .0121 2098-512 Additional service parts appear on following page. Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 78: Service Parts

    2166-369 Î 18.13 18.14 Jumper wire 2187-198 18.15 Battery Pack** 4067-223 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...
  • Page 79: Contact Information

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2010 Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. C • 10/10...