1. Top Vent - Horizontal Termination - (continued)
V Minimum
90° Elbow
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
H
+ H
MAX. =15 ft. (4.6 m)
1
2
V + H
+ H
MAX. = 40 ft. (12.2 m)
1
2
H
2
Figure 7.5
26
Top Vent - Horizontal Termination
Venting with 2 elbows
H
+ H
MAXIMUM
1
2
SLR-C
1 ft.
305 mm
2 ft.
610 mm
4 ft.
1.2 m
6 ft.
1.8 m
15 ft.
4.6 m
INSTALLED
HORIZONTALLY
Heat & Glo • SLR-C • 2292-900 Rev. D • 8/12
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.