Pressurized Combustion Chamber System Operational Checklist; Troubleshooting Chart - Kenmore 153.332620 Use & Care Manual

Gas water heater 40 & 50 gallon tall
Hide thumbs Also See for 153.332620:
Table of Contents

Advertisement

Pressurized Combustion Chamber System
Operational Checklist
1.
Manifold gasket properly sealed.
2.
Viewport not damaged or cracked.
3.
Combustion chamber free of debris and undamaged.
4.
Manifold component block properly installed.
PROBLEM
NO HOT WATER
INSUFFICIENT HOT WATER
SLOW HOT WATER
RECOVERY
WATER TOO HOT
BURNER FLAME
YELLOW - LAZY
BURNER FLAME FLOATS
AND LIFTS OFF PORTS
COMBUSTION ODORS

TROUBLESHOOTING CHART

POSSIBLE CAUSE(S)
1. Transformer unplugged.
2. No power at outlet.
3. Thermostat defective.
4. Air Intake Chamber Fan defective.
5. Pressure Switch defective.
6. Gas Valve/Thermostat Switch in "OFF
POSITION".
1. Thermostat set too low.
2. Thermostat defective.
3. Heater undersized.
4. Low gas pressure.
5. Incoming water is unusually cold.
6. Leaking hot water pipes or fixtures.
1. Low gas pressure.
2. Improper calibration.
3. Thermostat set too low.
4. Water heater too small.
5. Wrong piping connections.
6. Wasted hot water.
1. Thermostat set too high.
1. Dirt in burner ports.
2. Combustion air path restricted.
3. Not enough dilution air for proper com-
bustion.
4. Main burner line clogged.
5. Obstruction in main burner orifice.
6. Burner flame too high.
7. Flame burns at orifice/thermostat not
functioning properly.
8. Low gas pressure.
1. Orifice too large/wrong orifice.
2. High gas pressure.
3. Water heater flue or vent system
blocked.
4. Cold drafts.
1. Insufficient secondary air.
2. Water heater flue or vent system
blocked.
3. Heater installed in a confined area.
5.
No leaks at manifold connection.
6.
Manifold door screws securely tightened.
1. Plug transformer back into 120 VAC. outlet.
2. Repair service to outlet.
3. Replace Thermostat.
4. Replace Air Intake Chamber Fan Assembly.
5. Replace Pressure Switch Assembly.
6. Move Gas Valve/Thermostat Switch to "ON POSI-
TION".
1. Set temperature control higher.
2. Replace thermostat.
3. Reduce hot water use.
4. Contact dealer.
5. Allow more time for heater to reheat.
6. Have plumber check and repair leaks.
1. Check with gas utility company.
2. Replace thermostat.
3. Turn temperature dial to desired setting.
4. Install adequate heater.
5. Correct piping-dip tube must be in cold inlet.
6. Advise customer.
1. Set temperature control lower.
see, "WATER TEMPERATURE REGULATION",
section.
1. Turn off heater and gas, clean burner head.
2. Check intake venting arrangements for obstruc-
tions.
3. Check intake venting arrangements for obsruc-
tions.
4. Clean, locate source and correct.
5. Clean or replace orifice.
6. Check orifice and replace if necessary.
7. Replace thermostat
8. Check with gas utility company.
1. Replace with correct-orifice.
2. Check with gas utility company.
3. Clean flue and burner-locate source and correct.
4. Locate source and correct.
1. Provide ventilation to water heater. Check
flue.
2. Clean, locate source and correct.
3. Provide fresh air ventilation.
36
CORRECTIVE ACTION