Electrical; Electrical Connections; Solar Installation; Wiring Diagram - Kenmore 153.332620 Use & Care Manual

Gas water heater 40 & 50 gallon tall
Hide thumbs Also See for 153.332620:
Table of Contents

Advertisement

Electrical Connections

Before plugging in the water heater, always make sure:
The Voltage and frequency correspond to that specified on
the water heater.
The electrical outlet has the proper overload fuse or breaker
protection.
Unit is to connect to a 120VAC electrical supply outlet
(extension cord is not allowed).
WARNING
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.

Wiring Diagram

FIGURE 27.
Air Intake
Chamber Fan
Pressure
Switch
Electric Shock Hazard
Gas Control
Valve / Thermostat
Igniter/Flame
Sense Connector

ELECTRICAL

IMPORTANT: Do not use an extension cord to connect the water
heater to an electrical outlet.
The water heater and the outlet are properly grounded.
Installed in accordance with prevailing provisions of
local codes, or in the absence of such, National Electric
Code, ANSI/NFPS 70 current edition.
Completely fill the tank with water and check all connections for
leaks. Open the nearest hot water faucet and let it run for three (3)
minutes to purge the water lines of air and sediment and to ensure
complete filling of the tank. The electrical power may then be
turned on. Verify proper operation after servicing.

Solar Installation

If this water heater is used as a solar storage heater or as a
backup for the solar system, the water supply temperatures to
the water heater tank may be in excess of 120°F. A mixing valve
or other temperature limiting valve must be installed in the water
supply line to limit the supply temperature to 120°F.
NOTE: Solar water heating systems can often supply water with
temperatures exceeding 180°F and may result in water heater
malfunction.
CAUTION:
LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
24
Control Display
CAUTION:
DO NOT USE AN EXTENSION
CORD TO CONNECT THE
TRANSFORMER TO AN
ELECTRICAL OUTLET.
FV
Sensor
Power Supply
Transformer
Anode
Rod

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.332640

Table of Contents