CD10
HYDRAULIC
CORE DRILL
S
, O
M
afety
peratiOn and
aintenance
USer ManUaL
© 2010 Stanley Black & Decker, Inc.
New Britain, CT 06053
U.S.A.
58858 12/2012 Ver. 6

Advertisement

Table of Contents
loading

Summary of Contents for Stanley CD10

  • Page 1 CD10 HYDRAULIC CORE DRILL afety peratiOn and aintenance USer ManUaL © 2010 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 58858 12/2012 Ver. 6...
  • Page 2: Declaration Of Conformity

    Provisiones especiales: Disposizioni speciali: Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France. Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione Done at/Ort/Fait à/Dado en/Fatto a Stanley Hydraulic Tools, Milwaukie, Oregon USA...
  • Page 3: Table Of Contents

    REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER. For the nearest authorized and certified dealer, call Stanley Hydraulic Tools at the number listed on the back of this manual and ask for a Customer Service Representative.
  • Page 4: Safety Symbols

    Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULATIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel. 4 ► CD10 User Manual...
  • Page 5: Safety Precautions

    140 °F/60 °C. Operation at higher oil temperatures tions in the space provided in this manual. can cause operator discomfort and may cause dam- The CD10 Hydraulic Core Drill will provide safe and age to the tool. dependable service if operated in accordance with the •...
  • Page 6: Tool Stickers & Tags

    OPERATION MANUAL. OPERATION MANUAL. TAG TO BE REMOVED ONLY BY TAG TO BE REMOVED ONLY BY TOOL OPERATOR. TOOL OPERATOR. SEE OTHER SIDE SEE OTHER SIDE SAFETY TAG P/N 15875 (Shown smaller then actual size) 6 ► CD10 User Manual...
  • Page 7: Hose Types

    HOSE SAFETY TAGS To help ensure your safety, the following DANGER tags are attached to all hose purchased from Stanley Hydraulic Tools. DO NOT REMOVE THESE TAGS.
  • Page 8: Hose Recommendations

    HOSE RECOMMENDATIONS 8 ► CD10 User Manual...
  • Page 9: Htma Requirements

    2000 psi 2000 psi 2000 psi (at the power supply outlet) (172 bar) (138 bar) (138 bar) (138 bar) (138 bar) NOTE: These are general hydraulic system requirements. See tool specification page for tool specific requirements CD10 User Manual ◄ 9...
  • Page 10: Operation

    Maximum water pressure is 2. Make certain that the hydraulic power source is 60 psi/4 bar. equipped with a relief valve set to open at 2100– 5. Finally connect the tool to the power source. 2250 psi/145–155 bar. 10 ► CD10 User Manual...
  • Page 11 You may continuously control the advance motion of the drill by adjusting the star knob at the side of the drilling stand. 11. To switch off the machine, unlock the valve trigger fixing key. Then shut off the water supply. CD10 User Manual ◄ 11...
  • Page 12: Cold Weather Operation

    50 °F/10 °C (400 ssu/ 82 centistokes) before use. Damage to the hydraulic system or drill can result from use with fluid that is too viscous or too thick. 12 ► CD10 User Manual...
  • Page 13: Tool Protection & Care

    This can cause damage to internal seals. • Always replace hoses, couplings and other parts with replacement parts recommended by Stanley Hydraulic Tools. Supply hoses must have a mini- mum working pressure rating of 2500 psi/172 bar. CD10 User Manual ◄ 13...
  • Page 14: Troubleshooting

    Too low slip clutch torque. Inspect and replace slip clutch washers if necessary. Set torque to 20±1,5 Nm, 15±1 lbf.ft. See your authorized service dealer for repair. Do not overload drill to avoid wear of slip clutch. 14 ► CD10 User Manual...
  • Page 15 See your authorized dealer for repair. Water leaking out of shaft Output shaft seals worn. See your authorized dealer for repair. seal or side hole. Water pressure too high. Maximum water pressure is 60 psi/4 bar. Seal damaged. CD10 User Manual ◄ 15...
  • Page 16: Maintenance

    KEEP CONTAMINANTS SUCH AS DIRT AND GRIT AWAY FROM INTERNAL PARTS AT ALL TIMES. Always determine and correct the cause of the problem prior to reassembly. Further wear and tool failure can result if the original cause is not corrected. 16 ► CD10 User Manual...
  • Page 17: Accessories

    41616 Nut, Square 41621 Washer 41622 Distance Ring 41623 Handle ITEM # PART NO. DESCRIPTION 41608 Centering Aid, Includes Item 259 & 260 41609 Gas-pressure Spring with Buffer 41611 Extension Rod 56607 Centering Aid Tip CD10 User Manual ◄ 17...
  • Page 18: Cd10 Parts Illustration

    CD10 PARTS ILLUSTRATION CD10 Parts Illustration 18 ► CD10 User Manual...
  • Page 19: Cd10 Parts List

    GASKET 41272 OUTPUT SHAFT STOPCOCK 41273 SPUR GEAR 41586 CONNECTING PIECE 41274 NOTCHED WHEEL 41588 WATER STOP GARDENA 1/2 IN. 41275 SPUR GEAR 41251 HANDLE ASSY 41276 NEEDLE BEARING 41590 VALVE HOUSING ASSY 41277 BALL CD10 User Manual ◄ 19...
  • Page 20 COMPRESSION SPRING 41067 SNAP SPRING 41068 O-RING 41069 O-RING 41070 O-RING 41071 SCREW 41602 O-RING 41073 O-RING 52660 WASHER 41603 VALVE LEVER LOCKING ASSY 41604 HOUSING 41605 LATCH PIN 41606 COMPRESSION SPRING 41607 PUSH BUTTON 20 ► CD10 User Manual...
  • Page 22 Stanley Hydraulic Tools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www.stanleyhydraulic.com IMPORTANT To fill out a Product Warranty Recording form, and for information on your warranty, visit Stanleyhydraulic.com and select the Warranty tab.