Integrated Control Diagnostic Codes - Lennox MERIT ML180UHE Installation Instructions Manual

Merit series gas furnace upflow/horizontal air discharge
Hide thumbs Also See for MERIT ML180UHE:
Table of Contents

Advertisement

Integrated Control Diagnostic Codes

RED LED
Flash Code
Off
No power to control or board fault detected
On
Board fault detected,
1
Heartbeat
Control powered − displayed during all modes of operation if no errors are detected
1
Reverse Line Voltage Polarity
2
Improper Earth Ground
3
Burner failed to light, or lost flame during heat demand
4
Low Flame Signal − check flame sensor
5
Watchguard − burner failed to light, exceeded maximum number of retries or recycles.
6
Not Used
Primary or Secondary Limit Open or Watchguard Mode − Limit Switch Open longer than 3 min-
7
utes
8
Rollout Switch Open
9
Pressure Switch failed to close or opened during heat demand
10
Watchguard − Pressure Switch opened 5 times during one heat demand
11
Pressure Switch stuck closed prior to activation of combustion air inducer
12
Flame Sensed without gas valve energized
13
Low Line Voltage
Note 1
A "Heartbeat" is indicated by a "Slow Flash" − 1 sec on 1 sec off, repeating
Error codes are indicated by a "Rapid Flash" − the LED flashes X times at 1/2 sec on 1/2 sec
Note
off, remains off for 3 sec, then repeats
Last 10 error codes are stored in memory including when power is shut off to the unit. − To recall,
Note
press and release button, most recent will be displayed first, LED off for 3 sec, then next error
code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.
Diagnostic Codes / Status of Furnace
Notes
Page 38