Problem
The High tempera-
ture alarm light is
on.
There is too much
frost and ice.
The lid doesn't close
completely.
The lid is difficult to
open.
The lamp does not
work.
It is too warm in the
freezer.
Possible cause
The temperature of the
room that contains the ap-
pliance is too high for effi-
cient operation.
It is too warm inside the
freezer.
The cabinet has been re-
cently switched on and the
temperature is still too
high.
Products are not wrapped
properly.
The lid is not shut properly
or do not close tightly.
The temperature is not set
correctly.
The water drainage plug is
not correctly positioned.
There is excessive frost.
The lid gaskets are dirty or
sticky.
Food packages are block-
ing the lid.
The lid gaskets are dirty or
sticky.
The valve is blocked.
The lamp is defective.
The temperature is not set
correctly.
The lid does not close
tightly or it is not shut
properly.
Before freezing the appli-
ance was not precooled
sufficiently.
ENGLISH
Solution
Try to reduce the tempera-
ture in the room where the
appliance stands.
Refer to "High Temperature
Alarm".
Refer to "High Temperature
Alarm".
Wrap the products better.
Check if the lid closes well
and the gaskets are un-
damaged and clean.
Set a warmer temperature.
Position the water drainage
plug in the correct way.
Eliminate excess frost.
Clean the lid gaskets.
Arrange the packages in
the right way, see the stick-
er in the appliance.
Clean the lid gaskets.
Check the valve.
Refer to "Replacing the
lamp".
Set a lower temperature.
Check if the lid closes well
and the gasket is undam-
aged and clean.
Pre-cool the appliance for
enough time.
11