Warnings - Harman Home Heating DVC-500 Installation & Operating Manual

Coal stoker
Table of Contents

Advertisement

Installation
WARNING:
DO NOT INSTALL IN MOBILE
HOME SLEEPING ROOM
CAUTION:
THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
Open
fig. 8
7. Check the exterior of the termination for best fit
and screw to exterior and caulk with high grade
exterior caulking.
8. Complete any other exterior flue piping neces-
sary, using 4" pellet venting.
9. Back inside, place the 2 halves of the interior
wall trim plate over flue pipe. Using the black
pop rivets, fasten together, then slide it against
the wall and fasten it to the wall.
10. Replace the side door / rear cover assembly
with 6 black screws.
11. Complete the unit assembly and test.
fig. 9
Wall Trim Plate
Gasket
Wall
Termiation
Standard Wall
Termination
Wall Trim Plate
9