120/240V
30A
15. Full power switch – The generator is provided with a
full power switch. Figure 5 and Figure 6 show simplified
wiring diagrams of the dual voltage system.
When the full power switch is in the 120 volt (up)
position, you can access the full rated power of the
generator at 120 volts from the GFCI duplex receptacle
and the120V twist-lock receptacle, or a combination
of both receptacles as long as the total load does not
exceed the generating set capacity.
Figure 5. 120V Full Power Switch
Simplified Diagram (Up Position)
NOTICE
When the full power switch is in the 120V position, the
240V twist-lock receptacle cannot be used..
pAgE 18 — ga6HB/ga6HeB 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14)
15
GA-6HB
V
120
120
P
F
O
A
W
U
E
L
AC VOLTMETER
IDLE
R
T
CONTROL
120V
120
120
MANUAL RESET
30A
20A
AC CIRCUIT BREAKER
120V
120V/240V
GFCI PROTECTED
FULL POWER
SWITCH
120 V
120 V
20A
20A
IN SIMULTANEOUS USE 30 AMP MAX
Figure 4. Full Power Switch
ComPonenTs (GeneRaToR)
ON
0N
OFF
OFF
OPERATION
SWITCH
120/240V
30A
When the switch is in the 240 volt (down) position, you can
access half of the rated power of the generating set at 120
volts from the GFCI duplex receptacle and up to half of the
rated power of the set at 120 volts from 120V twist-lock
receptacle; or full rated power of the set at 240 volts from
the 240V twist-lock receptacle.
Figure 6. 240/120V Full Power Switch
Simplified Diagram (Down Position)
NOTICE
When using a combination of receptacles, total load
should not exceed the rated capacity of the generator.
NOTICE
In simultaneous mode use of receptaces, Figure 3,
items 3 and 10 (right most GFCI) is 30 amps maximum.
dO NOT exceed 30 amps when using this configuration.
15
GA-6HEB
V
120
ELECTRIC START
120
P
F
O
A
W
U
E
L
AC VOLTMETER
IDLE
R
T
CONTROL
120V
120
120
MANUAL RESET
30A
20A
AC CIRCUIT BREAKER
120V
120V/240V
GFCI PROTECTED
FULL POWER
SWITCH
120 V
120 V
20A
20A
IN SIMULTANEOUS USE 30 AMP MAX