Hoshizaki MODULAR CRESCENT CUBER KML-450MWH Instruction Manual page 19

Modular crescent cuber
Hide thumbs Also See for MODULAR CRESCENT CUBER KML-450MWH:
Table of Contents

Advertisement

10) Move the Service Switch to the "WASH" position.
11) Replace the Insulation Panel and the Front Panel in their correct positions.
12) Turn on the power supply and start the washing process.
13) Turn off the power supply after 30 minutes.
14) Remove the Front Panel.
15) Move the Service Switch to the "DRAIN" position.
16) Replace the Front Panel and turn on the power supply for 2 minutes.
17) Turn off the power supply and remove the Front Panel.
18) Move the Control Switch to the "ICE" position.
19) Replace the Front Panel in its correct position.
20) Turn on the power supply to fill the Water Tank with water.
21) Turn off the power supply after 3 minutes.
22) Remove the Front Panel.
23) Move the Control Switch to the "SERVICE" position; then move the Service Switch
to the "WASH" position
24) Replace the Front Panel in its correct position.
25) Turn on the power supply to rinse off the cleaning solution.
26) After 5 minutes, turn off the power supply.
27) Remove the Front Panel.
28) Move the Service Switch to the "DRAIN" position.
29) Replace the Front Panel and turn on the power supply for 2 minutes.
30) Turn off the power supply.
31) Remove the Front Panel.
32) Repeat the above steps 18) through 31) three more times to rinse thoroughly.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kml-450mah

Table of Contents