7) Connect the refrigerant lines to the appropriate fittings on the rack system first (if not
already brazed on), then at the icemaker.
If the couplings to the rack system are not Parker quick connect couplings, follow the
coupling manufacturer's instructions. Make a proper Parker quick connect coupling
connection as follows:
a. Remove the protective covers from the male fitting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil to the entire male fitting, including threads,
o-ring, and diaphragm, before making the connection. See Fig. 12.
Do not use thread sealant on the fittings. Use POE refrigerant oil only.
c. Make sure the male fitting and female coupling are properly aligned, then start the
connection by hand to ensure that it is not cross threaded.
d. Place a backup wrench on the back of the female coupling, then tighten the
connection with a wrench until it is tight. At this point, the nut has covered most of
the threads on the male fitting. CAUTION! Failure to use a backup wrench may
result in damage to the line set and possible refrigerant leaks.
e. Mark a reference line on the female coupling and the unit panel. Using a backup
wrench on the back of the female coupling, tighten the six-sided nut of the female
coupling an additional 1/6 turn. See Fig. 13.
8) Open the rack system service valves.
Rack System-Threaded Connection
Rack System-Braze Connection
Fig. 11
CAUTION
Male Threaded Fitting
Female Threaded Coupling
3/8" OD Suction Line
(Insulated)
1/4" OD Liquid Line
(Insulated)
Braze Conneciton
3/8" OD Suction Line
(Insulated)
1/4" OD Liquid Line
(Insulated)
Male Fitting
Female Coupling
(Charging Ports)
3/8" OD Suction Line
(Insulated)
1/4" OD Liquid Line
(Insulated)
Service Loop
24
Icemaker