Copyright 1999 Carrier Corporation
Product
Data
38TXA (60 Hz)
Air Conditioner
with Puron
(R-410A)
®
Sizes 024 thru 060
Carrier's WeatherMaker 38TXA with
Puron® provides a completely unique
collection of features which cannot be
matched by any other family of
equipment. The 38TXA family has been
designed as the first air conditioning
system utilizing Carrier's unique Puron®
refrigerant. The environmentally sound
refrigerant allows you to make a
responsible decision in the protection of
the earth's ozone layer. Carrier's
WeatherMaker systems with Puron® are
certified by the independent Green Seal
organization. These systems also meet the
Energy Star® guidelines for energy
efficiency.

FEATURES/BENEFITS

WeatherArmor III System is a three
component system—The casing steel is
galvanized and coated with a layer of zinc
phosphate. A modified polyester powder
coating is then applied and baked on,
providing each unit with a hard, smooth
finish that will last for many years.
All screws on the cabinet exterior are
SermaGuard coated for a long lasting,
rust-resistant, quality appearance.
The coil is protected with an enhanced
coil guard. With spacing of 3/8 in. and
construction of coated 12 gage wire, the
guard helps to protect from inclement
weather (hail), vandalism, and incidental
damage.
Puron® Environmentally Sound
Refrigerant — Is Carrier's exclusive
refrigerant designed to help protect the
environment. Puron® is an HFC
refrigerant which does not contain
chlorine that can harm the ozone layer.
The most important advantage of Puron®
refrigerant is that it has not been banned in
future air conditioning systems as the
traditional refrigerant R-22 has been.
Puron® refrigerant is in service in
thousands of systems providing highly
reliable, environmentally sound
performance.
High Efficiency Performance — Is
delivered through a combination of
features including Carrier's Puron®
refrigerant, unique scroll compressor, and
advanced heat transfer surfaces. Efficiency
ratings are 13 SEER (Seasonal Energy
Efficiency Ratio) with enhanced ratings of
up to 14 SEER. Sophisticated heat transfer
Form 38TXA-4PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38TXA

  • Page 1 Carrier’s WeatherMaker 38TXA with Puron® provides a completely unique collection of features which cannot be matched by any other family of equipment. The 38TXA family has been designed as the first air conditioning system utilizing Carrier’s unique Puron® refrigerant. The environmentally sound...
  • Page 2: Model Number Nomenclature

    The efficiency levels provided by Totally Enclosed Fan Motor — sound is the result of special attention to the 38TXA provide end users with lower Protected from adverse weather the air moving through the outdoor unit, a costs of operation than traditional air conditions.
  • Page 3: Physical Data

    Physical data UNIT SIZE-SERIES 024-30 030-30 036-30 042-30 048-30 060-31 Operating Weight (Lb) COMPRESSOR Manufacturer Copeland Type Scroll REFRIGERANT Puron® (R-410A) Control AccuRater® (Bypass Type) Charge (Lb) 6.00 6.00 6.88 8.75 10.13 12.00 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2400...
  • Page 4 Accessories ORDERING NO. DESCRIPTION KAATD0101TDR Time-Delay Relay — All Sizes KSALA0301410 Low-Ambient Pressure Switch — All Sizes P251-0083 (RCD) Low-Ambient Controller — All Sizes 32LT660004* (RCD) MotorMaster® Control — All Sizes KAAFT0101AAA† Evaporator Freeze Thermostat — All Sizes KAAWS0201AAA† Winter Start Control — All Sizes KSACY0101AAA Cycle Protector —...
  • Page 5 Accessory description and usage (Listed alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added. 2.
  • Page 6: Electrical Data

    Electrical data 60°C 75°C 60°C 75°C FUSE** OPER VOLTS* COMPR UNIT SIZE- WIRE WIRE LENGTH LENGTH OR CKT SIZE† SIZE† (Ft)‡ (Ft)‡ BKR AMPS SERIES V/PH 024-30 61.0 13.5 17.6 030-30 72.5 14.7 19.2 036-30 83.0 15.4 20.2 208/230/1 042-30 105.0 18.6 24.4...
  • Page 7 Dimensions...
  • Page 8 Combination ratings SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ CC5A/CD5AA030* 24,000 NONE — 13.00 13.00 11.10 CC5A/CD5AA024 24,000 NONE — 12.50 12.50 11.20 CC5A/CD5AW024 24,000 NONE —...
  • Page 9: Combination Ratings Continued

    Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ F(A,B)4ANF030 28,600 12.50 — 12.50 11.10 F(A,B)4ANF036 29,000 12.50 — 12.50 10.95 FF1(A,B)NA030 28,600 12.50 —...
  • Page 10 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ F(A,B)4ANF036 35,000 12.50 — 12.50 11.15 FG3AAA036 35,000 NONE — 12.20 12.20 10.95 FK4CNF002+Puron® (R-410A) TXV** 35,000 13.00...
  • Page 11 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ CD5AW036 35,000 13.50 — 13.50 11.70 CE3AA036 35,000 13.20 — 13.20 11.60 CE3AA042 35,000 13.50 —...
  • Page 12 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ COILS + 58MVP080-14 VARIABLE SPEED FURNACE CC5A/CD5AA042 40,500 13.00 — 13.00 11.40 CC5A/CD5AC048 40,000 13.00 —...
  • Page 13 Combination ratings continued SEER FACTORY- SUPPLIED Carrier Gas Furnace UNIT INDOOR TOT. CAP. ENHANCE- Standard or Accessory Accessory SIZE-SERIES UNIT BTUH MENT Rating TDR† TXV‡ CC5A/CD5AW060 47,000 NONE — 13.00 13.00 11.80 CD5AA048 46,000 NONE — 13.00 13.00 11.50 CE3AA048...
  • Page 14 † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in perfor- mance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Carrier furnaces are equipped with TDR except for the 58GFA.
  • Page 15 Detailed cooling capacities* CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 16 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 17 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 18 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 19 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 20 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 21 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 22 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 23 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 24 Detailed cooling capacities* continued CONDENSER ENTERING AIR TEMPERATURES °F EVAP Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡...
  • Page 25 Condenser only ratings* CONDENSER ENTERING AIR TEMPERATURES °F °F 38TXA024-30 25.9 24.5 23.1 21.7 20.3 18.9 17.5 16.0 75.0 85.0 95.0 105.0 115.0 125.0 135.0 145.0 1.30 1.48 1.68 1.90 2.13 2.39 2.66 2.96 28.7 27.1 25.6 24.1 22.5 21.0 19.4 17.7 75.0...
  • Page 26 Condenser only ratings* continued CONDENSER ENTERING AIR TEMPERATURES °F °F 38TXA042-30 41.4 39.2 37.0 34.8 32.5 30.2 27.8 25.3 72.3 82.0 91.8 102.0 111.0 121.0 130.0 140.0 1.85 2.10 2.39 2.72 3.07 3.46 3.89 4.36 45.4 43.0 40.6 38.2 35.7 33.2 30.6 27.8...
  • Page 27 System design summary 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4.
  • Page 28 Guide specifications Air-Cooled, Split-System Air Conditioner 38TXA 2 to 5 Tons Nominal GENERAL System Description Condenser fan motors will be totally enclosed, 1-phase Outdoor-mounted, air-cooled, split-system air conditioner type with class B insulation and permanently lubricated unit suitable for ground or rooftop installation. Unit consists bearings.
  • Page 29: Typical Installation

    Typical installation AIR CONDITIONER COMFORT VENTILATOR™ COMFORT ZONE™ II EQUIPMENT CONTROLLER HUMIDIFIER FURNACE COIL FURNACE AIR CLEANER A98600...
  • Page 32 Indianapolis, IN 46231 3-99 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 32 Catalog No. 523-739 Printed in U.S.A. PC 101 Form 38TX -4PD Replaces: 38TXA-3PD 3a 2a...

Table of Contents