When the SCSI channel is set to "20," if a software key which
does not correspond to the setup is entered, the setup of "20" is
changed to "1."
26 - 12
Purpose
Setting
Function
Used to enter the Diagnosis function key input.
(Purpose)
Item
Operation
Operation/
1. After entering the sub code of the simulation, enter
Procedure
the software key in the obtained frame of "NEW."
2. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
is stored.
3. The Alert/Status E-Mail send function with attached data of the
Remote E-Mail Diagnosis System is enabled.
26 - 13
Purpose
Setting
Function
After completion of copier job in copier interruption dur-
(Purpose)
ing a printer job, the print job is resumed in synchroni-
zation with the auto clear timer (key operation) setup
time [10-240]. By making the setup below, the print job
is resumed in 0 sec. (However, the auto clear function
is enabled with the setup time of key operation. Also,
this simulation and auto clear are not synchronized.)
Item
Operation
Operation/
When this simulation is executed, the current set value
Procedure
is displayed. At that time, the set value can be changed
with the 10-key.
When the [OK] key is pressed, the current set value is
stored in the EEPROM.
3/13/2000
26 - 22
Purpose
Setting
Function
Used to set the specification (language display) for the
(Purpose)
destination. (Excluding the Japan models.)
Item
Specifications
Operation/
Select the language to be used according to the table
Procedure
below.
Display
ENG.(US)
ENG.(UK)
FRENCH
SPANISH
GERMAN
ITALIAN
SWEDISH
DUTCH
26 - 32
Purpose
Setting
Function
When the variable speed fan motor is in the ready state
(Purpose)
and the process temperature is in the range of 36° –
45°, the PWM duty is set in percentage.
Item
Operation
Operation/
When this simulation is executed, the current set value
Procedure
is displayed. At that time, select the fan motor with [­]
key and [¯] key. Then the set value can be changed
with the 10-key.
When [­] key or [¯] key is pressed, the current set value is stored in
the EEPROM.
VFM1&2&4
Adjustment range of 50 – 100% in 1% increment
PCFM VFM5&6 Adjustment range of 50 – 100% in 1% increment
26 - 44
Purpose
Setting
Function
Used to set the model of the unit which is connected to
(Purpose)
the SCSI I/F of ICU PWB.
Section
ICU
Item
Specifications
Operation/
A is at the left of B when viewed from the rear side.
Procedure
0:
No connection
1:
Printer controller
3:
External printer controller
7 – 54
Language
English(US)
English(UK)
French
Spanish
German
Italian
Swedish
Dutch
Interface/Communication