[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Connection to Check the Camera Section
To check the camera section, set the camera to the "Forced camera power ON" mode.
Setting the "Forced Camera Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjustment remote
commander.
Note: If the machine malfunctions (the operating mode changes by itself), connect the FK-1000 block,
CF-1000 block/CF-077 board.
Control switch block (FK-1000) (12P)
When you operate the zoom,
connect the FK-1000 block to
CN710 of VC-251 board.
Mechanism deck
FP-257 flexible board
Audio
Monitor TV
Video
Info lithium battery
(L series)
Adjustment remote
commander (RM-95)
5 1
- 2
V C
A/V out jack
CPC-jig for BX/BK
(J-6082-521-A)
Exiting the "Forced Camera Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote
commander.
3) Select page: 0, address: 01, and set data: 00.
VC-251 board
AC power
adaptor
Battery terminal board
FFC-295 flexible
flat cable (24P)
2-13
AC IN
Flexible board
(from lens block) (24P)
FP-259 flexible board (14P)
Lens block
(TRV model)
FFC-295 flexible
flat cable (24P)
Control switch block
(CF-1000)
(TR model)
Liquid crystal
display panel,
LCD holder
CF-077 board