Daewoo DWF-5590DP Series Service Manual page 37

Programmable washing machine
Table of Contents

Advertisement

BUZZER UNIT
1) CIRCUIT DIAGRAM
2) EXPLANTION OF CIRCUIT
• After the button action and total process ends, BUZZER is active.
• It is active directly with offering an output the frequency waveform of 2 KHz from the MICOM terminal No. 7
• The R7 is 'PULL UP' resistance, and R8 is restrict resistor of Q1 base current, and R5 is resistance of excess current
under phenomenon of short circuit, when the electric current changes abruptly according to the condenser component
of piezoelectric element, and R8 remove the phenomenon of abnormal oscillation by preventing the collector floating
state of Q1.
• The waveform in the part of the BUZZER DRIVE TR Q1 collector.
BUZZER INPUT UNIT
1) CIRCUIT DIAGRAM
LOAD
SELECT
37
M
R7, 10k
I
7
C
R6,1k
O
M
12V
0V
D19
D11
SW4
SW8
D12
SW3
SW7
D18
OPTION : PUMP
D25
SW6
D24
1N4148
SW5
R8,620
R5,220
Q1
C3202Y
BUZZER
WES27-20P
t
f = 2 KHz
10
7
11
8
12
5
13
4
14
3
I.C6
15
2
ULN-2004
16
1
9
8
D19
SW12
D22
R66,220
D18
R67,220
D17
R68,220
SW9
D16
R69,220
12V
50
S23
51
S24
52
S25
53
S26
54
S27
RA1(4X473)
57
P100
58
P01
59
P02
60
P03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwf-5590d series

Table of Contents