Honeywell MAGICSTAT 3355 Owner's Manual page 25

Weekday/weekend (5-day/ 2-day) programmable heat and/or cool low voltage (20 to 30 vac) thermostat and mounting plate
Table of Contents

Advertisement

2-WIRE HEAT-ONLY (JUMPER INTACT)
A
B
HEATING
RELAY OR
VALVE COIL
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
C
D
W
Y
G
Rc
R
L1
(HOT)
1
L2
4-WIRE HEAT/COOL (JUMPER INTACT)
JUMPER
HEATING
RELAY OR
VALVE COIL
M8793
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
25
A
C
B
D
W
Y
G
R
COOLING
CONTACTOR
COIL
FAN
RELAY
JUMPER
Rc
L1
(HOT)
L2
M8794
69-1012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct3355a1003