Thermostat Specification and Selection Guide (table rows continued from facing page)
Air Connections**
T-4002
Two
Supply and Output
T-4003
Three
Supply, Output,
and Remote Reset
Input
T-4054
Two
Supply and Output
T-4100
One
Restricted
Supply/Output
T-4110
Two
Control and
Aspirator
T-4506
Two
Supply and Output
T-4516
Three
Supply, Output,
and Switchline
T-4600
Two-Restricted
Supply/Output for
Heating and
Cooling
T-4756
Two
Supply and Output
Elements
*Supply Pressure
**Air Connections
Ambient Operating Temp Limits
Ambient Storage Temp Limits
***lb x 0.454 = kg
The performance specifications are nominal and conform to acceptable industry standards. For application at
conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall
not be liable for damages resulting from misapplication or misuse of its products.
Dial
Special Features
Ranges
55 to 85° F
Volume Amplifier,
Pneumatic Feedback
55 to 85° F
Volume Amplifier,
Remote Readjustment--
from .15 to 2.5°F/PSI
(1.8 to 30°C/kPa)
Two dials
Energy Manager,
55 to 85° F
Pneumatic Feedback,
Adjustable Deadband--
between 5 and 12 PSIG
(35 and 84 kPa)
55 to 85°F or
Pneumatic Feedback,
13 to 29°F
°F and °C Thermometer
66 to 82°F
Ball Control Port ,
(19 to 28°C)
Flexible Setpoint, Lever,
Adjustable Sensitivity
Two dials
Volume Amplifier,
55 to 85°F
Pneumatic Feedback,
Manual Indexing Switch
(optional),
Element Identification
Labels
Two dials
Volume Amplifier,
55 to 85°F
Pneumatic Feedback,
Manual Indexing Switch
(standard),
Element Identification
Labels
50 to 80°F
Energy Manager,
and 63 to
Individual Adjustments
93°F or
for Heating and Cooling,
10 to 27°C
Element Identification
and
Labels
17 to 34°C
Two dials
Volume Amplifier,
55 to 85°F
Models Available with
Factory Stops and
WARM-COOL dials,
Element Identification
Labels
Single or Dual Bimetal Strips
Air Supply Must Be Clean, Dry, and Oil Free
Barbed Fittings for 5/32 in. O.D. Polytubing
-20 to 130 F (-29 to 54 C)
-20 to 150 F (-29 to 66 C) or -20 to 130 F for Units with Thermometers
Code No.
Suffix
T-4002-
ActionVert. Horiz
DIR
201
REV
202
T-4003-
Horiz
DIR,DR
201
REV,RR
203
T-4054-
Horiz or Vert.
DIR
1
REV
2
T-4100-
F° Dial
(Vert. Mtg.)
DIR
1
REV
2
T-4110-
w/o aspirator
DIR
1
REV
3
T-4506-
mtg. w/switch w/o switch
DIR
Horiz. 201
Vert. 202
REV Horiz. 209
T-4516-
DIR
Horiz.
201
Vet.
202
T-4600-
Action
F° Dial
(Vert. Mtg.)
DIR
1
REV
2
DIR and REV 5
T-4756-
Action
Mtg. F° Dial W-C Dial
DIR
Horiz. 201
@15 PSIG
Vert.
DIR
Horiz. 205
@20 PSIG
Vert.
Shipping
Weight lb.***
0.4
203
204
0.4
Horiz.
Mtg.
0.4
C° Dial
0.2
3
4
w/aspirator
0.2
2
4
0.4
203
204
217
0.4
C° Dial
0.3
3
4
6
0.4
216
202
217
206
T-4000 Product Bulletin
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-4003T-4054T-4100T-4110T-4506T-4516 ... Show all

Table of Contents