235. (11101011) Phase 6 - Lid Lock Short Circuit
Lid Lock fault, not activated when instructed to by the Motor Control
Module.
Primary Fault:
Action:
236. (11101100) Phase 6 - Incompatible EEPROM Version
Failure to start and fault immediately displayed.
Primary Fault:
Action:
237. (11101111) Phase 6 - Temperature Sensor Error
The electronics have picked up a continuity problem, same as fault
code 10 or 41.
Primary Fault:
Action:
Secondary Source: Motor Control Module has failed to read the
Action:
238. (11101110) Phase 6 - Lid Lock Fail In-line Test (1)
Final on line tests, final check before going to the field.
239. (11101111) Phase 6 - Lid Lock Fail In-line Test (2)
Final on line tests, final check before going to the field.
240. (11110000) Phase 6 - Hall Out of Order. RPS Fault
Same as previous Hall Error faults, just an extra fault code for Phase
6. See fault codes 130 and 131 for directions.
Lid Lock mechanism has jammed or failed.
Check resistance across the connections,
should be around 73 ohms. If not within 5
ohms, replace the Lid Lock.
Motor Control Module is the wrong one.
Replace Motor Control Module.
The sensor has failed either in the harness or
connection to the thermistor.
Replace the Thermistor (temperature sensor).
temperature. Check connections.
Replace Motor Control Module if connections
look fine and the fault still occurs.