NOTES:
When performing any of the arming commands, if there are faults in any of
the partitions, none of the partitions will arm. These faults must be corrected
or bypassed before attempting to arm.
When performing either a STAY or INSTANT arm command the system
always arm in mode 1 (see page 36 Arming Perimeter Only for a detailed
explanation of the STAY arming modes.
The user cannot execute another panel linking mode. To execute another
panel linking mode or to access a different remote panel, the user must first
exit this mode (return to the original control panel).

Multi-Panel View Mode

To access the multi-panel view mode, perform the following steps:
1.
Enter your security code + #
2.
The keypad displays the following:
where "12345678" are the panel id #s and "xxxxxxxx" is the overall status
of each panel. Possible status indications include:
A = Armed Away
I = Armed Instant
B = Bypassed/Ready ✴ = Alarm
F = Fire Alarm
C = Comm Fail
NOTE: See the table that follows for priority of displays.
Use the following keys to perform a function in the Multi-Panel View Mode:
Press 1 to attempt to disarm all partitions on all panels.
Press 2 to attempt to arm AWAY all partitions on all panels.
Press 3 to attempt to arm STAY all partitions on all panels.
Press 4 to attempt to arm MAXIMUM all partitions on all panels.
Press 7 to attempt to arm INSTANT all partitions on all panels.
Accessing Other Panels (cont'd)
ALLPANEL
1 2 3 4 5 6 7 8
STATUS
x x x x x x x x
S = Armed Stay
R = Ready
P = AC Power Failure L = Low System Battery
+ 8
+ 7
M = Armed Maximum
N = Not Ready
T = Trouble
– 29 –