SW-F2 No. 1 CNG detection in STAND-BY mode
When setting to "1", the CNG signal detection function during standby
stops.
SW-F2 No. 2, No. 3 Number of CNG detect (AM mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 4, No. 5 Number of CNG detect (STAND-BY mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 6 ~ No. 8 Reserved
Set to "0"
SW-G1 No. 1 ~ No. 8 Reserved
Set to "0"
SW-G2 No. 1 ~ No. 8 Reserved
Set to "0"
SW-G3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-G4 No. 1 ~ No. 8 Reserved
Set to "0".
SW-H1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-H2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I4 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I5 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I6 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I7 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I8 No. 1 ~ No. 8 Reserved
Set to "0".
SW-J1 No. 1 Sender's phone number setting
Used to make a choice of whether the registered sender's phone number
can be changed or not. If the switch is set to "1", new registration of the
sender's phone number is disabled to prevent accidental wrong input.
SW-J1 No. 2 Summer time setting (Daylight saving)
Used to set YES/NO of automatic clock adjustment for Summer
time(Daylight saving time).
SW-J1 No. 3, No. 4 Ringer Volume
Used to adjust ringing volume.
SW-J1 No. 5, No. 6 Speaker Volume
Used to adjust sound volume from a speaker.
SW-J1 No. 7, No. 8 Reserved
Set to "0".
SW-J2 No. 1, No. 2 Handset receiver volume
Used to adjust sound volume from a handset receiver volume.
SW-J2 No. 3 ~ No. 8 Reserved
Set to "0".
SW-J3 No. 1 ~ No. 3 Communication results printout
(Transaction report)
It is possible to obtain transaction results after each communication.
Normally,the switch is set (No. 1 : 0, No. 2 : 0, No. 3 : 0) so that the
transaction report is produced only when a communication error is en-
countered.
If No.1 was set to 0 and No. 2 to 1 and No. 3 to 0, the transaction report
will be produced every time a communicaion is done, even if the
communicaion was successful.
Setting No. 1 to 0 and No. 2 to 1 and No. 3 to 1 will disable this function.
No transaction report printed.
SW-J3 No. 4 Time format
When set to "0", 24hour time format is used.
When set to "1", 12hour time format is used.
SW-J3 No. 5 Date format
When set to "0", Day-Month-Year format is used.
When set to "1", Month-Day-Year format is used.
SW-J3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering diag mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED key
is pressed, the switch is changed from the stand-by state to the diag
mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".