General Description; Prior To Installation - American Standard Selectronic Proximity Urinal Flush Valve 6063.051 Installation Instructions Manual

Selectronic proximity urinal flush valve 0.5 & 1.0 gpf

Advertisement

Fig. 1
Roughing-in Dimensions
72mm
(2-7/8)
116mm
(4-5/8)
MANUAL
OVERRIDE
BUTTON
293mm
(11-1/2)
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver (For adjusting Supply Stop)
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
SUPPLY
DN 19mm
(3/4" I.P.S.)
115mm-134mm
(4-1/2 TO 5-1/4)
409mm
(16-1/8)
FOR 3/4" TOP
SPUD FIXTURES
DETECTION ZONE
400mm-800mm
(15-3/4 TO 31-1/2)
FINISHED WALL
57mm
(2-1/4 MIN.)
15˚
Fig. 2
1
5
7
• Flush all water lines prior to operation (See Step 4). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
2

GENERAL DESCRIPTION:

SELECTRONIC™
PROXIMITY URINAL
FLUSH VALVE
Exposed Flushometer
for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-type flush
valve with proximity operation and
manual override.
Operates on DC
(b at ter y) pow er . R eco mm en ded
operating pressure 35 to 80 psi. Can
install left or right-handed. Detection
Zone can also be adjusted manually, or
with optional remote control.
Right or Left Hand Installation