Deflection (16:9 Mode) Adjustment; Confirmation; 525P Deflection Adjustment / Confirmation - Panasonic TX-29P180B Service Manual

Table of Contents

Advertisement

6.5.
DEFLECTION (16:9 MODE) ADJUSTMENT / CONFIRMATION
6.5.1.
DATA SETTING (16:9)
1. Copy the adjusted data of 100i / 4:3 mode to 100i / 16:9 in the table 1 (Except H-POS, V-S-Correct).
2. Copy the adjusted data of 120i / 4:3 mode to 120i / 16:9 in the table 1 (Except H-POS, V-S-Correct).
3. Copy the adjusted data of 50p / 4:3 mode to 50p / 16:9 in the table 1 (Except H-POS, H-AMP, V-S-Correct, C-Correct) and copy
the data of 100i / 4:3 to 50p / 16:9 about H-AMP and C-Correct.
4. Copy the adjusted data of 60p / 4:3 mode to 60p / 16:9 in the table 1 (Except H-POS, H-AMP, V-S-Correct, C-Correct) and copy
the data of 120i / 4:3 to 60p / 16:9 about H-AMP and C-Correct.
6.5.2.
V-AMP (16:9) ADJUSTMENT
1. Receive PAL monoscope pattern.
2. Set the aspect to 16:9
3. Set scan mode to 100 Hz
4. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (100i / 16:9).
5. Set scan mode to progressive.
6. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (50p / 16:9).
7. Receive NTSC monoscope pattern.
8. Set scan mode to 100 Hz.
9. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (120i / 16:9).
10. Set scan mode to progressive.
11. Confirm that A, B in Fig. 7 is 5.0 cm ± 1 cm. If not, adjust V-AMP (60p / 16:9).
6.6.

525p DEFLECTION ADJUSTMENT / CONFIRMATION

6.6.1.
V, H-HOLD CONFIRMATION
1. Receive 525p signal through Yuv input.
2. Confirm V, H-hold is normal.
Fig. 6
Fig. 7
21
TX-29P180X

Hide quick links: