AC Operation
1. Start the engine (refer to page 24) and make sure the pilot lamp comes on.
If not, the filament may be burnt out.
2. Plug in the appliance.
CAUTION:
Substantial
overloading
will switch off the circuit breaker.
Marginal overloading
may not switch off the circuit breaker, but it will
shorten the service life off the generator.
Be sure that all appliances
are in good working order before connecting
them to the generator.
If an appliance
begins to operate abnormally,
becomes
sluggish,
or stops suddenly,
turn off the generator
engine
switch immediately.
Then disconnect
the appliance
and examine it for
signs of malfunction.
3. Check the frequency meter to verify that the generator is operating at 60Hz.
If it is not, turn the governor adjustment screw to increase or decrease
engine speed until the correct frequency is obtained (meter bar next to 60
will vibrate).
NOTE: If an overloaded circuit trips the AC circuit breaker, reduce the
electrical load on the circuit, and wait a few minutes before resuming
operation.
The green indicator inside the circuit breaker button will pop out to show that
the circuit breaker has switched off.
Push the button in to reset the circuit breaker.
AC CIRCUIT BREAKER
GOVERNOR
ADJUSTMENT
SCREW
16
PliOT
FREbUEiliZY'
1
LAMP
METER