Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert system will automatically
stop the engine (the engine switch will remain the ON position). If the engine
stops and will not restart, check the engine oil level (p.20) before trouble
shooting in other areas.
DIPSTICK
AC Circuit Breaker
The AC circuit Breaker automatically shuts off the AC receptacle circuit when
the generator is overloaded, when there is a problem with the electrical load;
or the connections between the electrical load and the generator are improper.
AC CIRCUIT BREAKER
13